transceiver test system specification sheet jfw model 50PMA-015 jfw industries, inc. phone: 317-887-1340 sales@jfwindustries.com www.jfwindustries.com frequency range 1000-2000 mhz configuration 4 port transceiver test system (see block diagram 092-5093) impedance 50 ohms nominal attenuation range 0-127 db in 1 db steps attenuation steps 1, 2, 4, 8, 16, 32, and 64 db vswr 1.6:1 maximum attenuation accuracy 0.4 db or 2% of programmed (whichever is greater) insertion loss 17.0 db maximum 13.0 db typical @ 1000 mhz 15.5 db typical @ 2000 mhz isolation (power dividers) 20 db minimum (port to po rt) rf input power +24 dbm average switching speed 10 microseconds typical (after command is received and processed) (3 milliseconds typical processing time) ac supply 100-240 vac @ 47-63 hz remote control ethernet (10/100) remote commands pause (pausex) variable handover (vhnd av aw vx vy tz) feedback handover (fhnd av aw vx vy tz) fade attenuator (fax y z t) feedback fade (ffax y z t) set attenuator (sax y) read attenuator (rax) identification (idn) rf connector sma or n female operating temperature range 0oc to +50oc physical size see outline drawing 092-5092 04/30/2008 trs 04/30/2008 ecr/ecn # date rev appr / date ecr/ecn # dat e rev appr / date 15916 05/28/2008 a trs 05/28/2008 16179 08/07/2008 b trs 08/07/2008 jfw form e-7-f rev f page 1 of 1
|